INTERLEUKIN-2 RECEPTOR

General Information

Lab Order Codes:

IL2R

Synonyms:

IL 2 Receptor

CPT Codes:

84238 – Receptor assay, non-endocrine

Test Includes:

Interleukin-2 Receptor level reported in U/mL.

Logistics

Test Indications:

Clinical conditions in which elevated soluble IL-2R levels are detected include AIDS, autoimmune disease, sarcoidosis, and a variety of leukemias and lymphomas. In HIV positive individuals, IL-2R is elevated during the asymptomatic phase as well as during persistent generalized lymphadenopathy and symptomatic phases. IL-2R detection may be useful in measuring T cell activation and monitoring HIV pathogenesis. Elevated IL-2R levels have clinical and prognostic significance in patients with malignant lymphoma, non-Hodgkin’s lymphoma, B cell and undifferentiated lymphomas.

Lab Testing Sections:

Chemistry - Sendouts

Referred to:

Mayo Medical Laboratories forward to Focus Technologies (Test# 90021/FIL2R)

Phone Numbers:

MIN Lab: 612-813-6280

STP Lab: 651-220-6550

Test Availability:

Daily, 24 hours

Turnaround Time:

1 - 9 days

Special Instructions:

N/A

Specimen

Specimen Type:

Blood

Container:

Red top tube
Alternate tubes: Green top (Heparin), Lavender top (EDTA) and Yellow (ACD) tubes

Draw Volume:

6 mL (Minimum: 1.5 mL) blood

Processed Volume:

2 mL (Minimum: 0.5 mL) serum/plasma

Collection:

Routine venipuncture

Special Processing:

Lab Staff: Centrifuge specimen and separate serum/plasma aliquot into a screw-capped round bottom plastic vial. Store and ship at frozen temperatures. Forward promptly.

Patient Preparation:

None

Sample Rejection:

Mislabeled or unlabeled specimens

Interpretive

Reference Range:

<970 U/mL

Critical Values:

N/A

Limitations:

This assay is performed using a kit labeled “For Research Use Only” by the kit manufacturer. The kit’s performance characteristics have been established and validated by Focus Diagnostics for in-vitro diagnostic use.

Methodology:

Enzyme-linked Immunosorbent Assay (ELISA)

References:

Mayo Medical Laboratories Web Page January 2013

Focus Diagnostics Web Page January 2013

Updates:

3/18/2004: Test moved from Specialty Laboratories to Mayo Medical Laboratories forward to Focus Technologies. Note changes in CPT code, Methodology, and reference range.
9/16/2008: CPT update, previously reported at 83520



  Lab Test Directory
    Chemistry
    Coagulation
    Flow/Immunology
    Hematology
    Microbiology/ Virology
    Other Fluids
    Pathology
    Serology
    Transfusion Services
    Urine/Stool

  Search Lab Test Directory
    List All Documents

  Lab Staff

  E-mail Lab Services