Lab Dept:
|
Chemistry
|
Test Name:
|
LIPID PROFILE
|
General Information
|
Lab Order Codes:
|
LIPL
|
Synonyms:
|
Lipid Panel
|
CPT Codes:
|
80061 – Lipid panel
|
Test Includes:
|
Total Cholesterol, Triglycerides, HDL Cholesterol and LDL Cholesterol (measured)
|
Logistics
|
Test Indications:
|
Evaluation of cardiovascular risk.
|
Lab Testing Sections:
|
Chemistry
|
Phone Numbers:
Minneapolis:
Saint Paul:
|
|
612-813-6280
|
651-220-6550
|
Test Availability:
|
Daily, 24 hours
|
Turnaround Time:
|
2 hours
|
Special Instructions:
|
See Patient Preparation
|
Specimen
|
Specimen Type:
|
Blood
|
Container:
|
Green (Li Heparin) or Red top tube
|
Draw Volume:
|
1.5 mL (Minimum: 0.6 mL) blood
|
Processed Volume:
|
0.5 mL (Minimum: 0.2 mL) plasma/serum
|
Collection:
|
Routine venipuncture
|
Special Processing:
|
Lab Staff: Centrifuge specimen, remove plasma/serum aliquot into a plastic sample cup. Sample to be run within 2 hours.
|
Patient Preparation:
|
Patient should be on a stable diet for 3 weeks, and fast 9-12 hours before collection, recommended.
|
Sample Rejection:
|
Mislabeled or unlabeled specimen
|
Interpretive
|
Reference Range:
|
Reference Ranges:
|
2 – 17 yrs
|
≥18 yrs
|
Total Cholesterol:
(mg/dL)
|
Desirable
|
<170
|
<200
|
Borderline high:
|
170 - 199
|
200 - 239
|
High
|
≥200
|
≥240
|
HDL Cholesterol:
(mg/dL)
|
Low:
|
<40
|
<40
|
Normal:
|
40 – 60
|
40 – 60
|
Desirable:
|
>60
|
≥60
|
LDL Cholesterol:
(mg/dL)
|
Acceptable:
|
<110
|
<100
|
Near optimal:
|
NA
|
100 - 129
|
Borderline:
|
110 – 129
|
130 – 159
|
High:
|
≥130
|
≥160
|
Triglycerides:
(mg/dL)
|
|
0 – 9 yrs
|
10 – 17 yrs
|
≥18 yrs
|
Acceptable:
|
0 - 75
|
<90
|
<150
|
Borderline:
|
75 - 99
|
90 - 129
|
150 – 199
|
High:
|
≥100
|
≥130
|
≥200
|
Note: The National Education Program (NCEP) has set the above guidelines for lipids (total cholesterol, triglycerides, HDL, and LDL cholesterol.
|
Critical Values:
|
N/A
|
Limitations:
|
N/A
|
Methodology:
|
Enzymatic colorimetric; dextran sulfate, direct measure LDL
|
References:
|
CHOL Flex™ reagent cartridge insert sheet Siemens Healthcare Diagnostics Inc. (2008-03-04) Rev I 717027.001 – US
TGL Flex® reagent cartridge insert sheet Siemens Healthcare Diagnostics Inc (2008-02-29) C 717069.101 – US
AHDL Flex™ reagent cartridge insert sheet, Siemens Healthcare Diagnostics Inc. (2009-07-22) Rev A, PN 717048.002 –US
ALDL Flex® reagent cartridge insert sheet PN 717731.001 (Issue Date 2008-02-13) Rev. B
US Department of Health and Human Services (May 2001) National Institutes of Health Publication # 01-3305
US Department of Health and Human Services, Summary Report of the Expert Panel on Integrated Guidelines for Cardiovascular Health and Risk Reduction in Children and Adolescents:7.
Mayo Medical Laboratories (1/6/2012) online test catalogue
|
Updates:
|
2/21/2012: Testing moved to inhouse test at Children’s, previously listed as referred to Mayo Medical Laboratories.
|