Lab Dept:
|
Chemistry
|
Test Name:
|
TSH, SENSITIVE
|
General Information
|
Lab Order Codes:
|
TSH
|
Synonyms:
|
Thyroid Stimulating Hormone; Ultra sensitive TSH
|
CPT Codes:
|
84443 – Thyroid stimulating hormone (TSH)
|
Test Includes:
|
TSH concentration reported in uIU/mL.
|
Logistics
|
Test Indications:
|
TSH is synthesized and secreted by the anterior pituitary. TSH is responsible for stimulating cell reproduction and hypertrophy. Secondly, TSH stimulates the thyroid gland to synthesize and secrete T3 and T4. The measurement of circulating TSH is important in evaluating hyperthyroidism.
|
Lab Testing Sections:
|
Chemistry (all specimens tested on the St. Paul campus)
|
Phone Numbers:
Minneapolis:
Saint Paul:
|
|
612-813-6280
|
651-220-6550
|
Test Availability:
|
Daily, 24 hours
|
Turnaround Time:
|
1 – 3 days, test performed Monday – Friday.
|
Special Instructions:
|
N/A
|
Specimen
|
Specimen Type:
|
Blood
|
Container:
|
Red top (plain, no gel) tube
|
Draw Volume:
|
1.5 mL blood
|
Processed Volume:
|
0.5 mL serum
|
Collection:
|
Routine venipuncture
|
Special Processing:
|
Lab Staff: Centrifuge specimen, remove serum aliquot into a plastic sample cup. Store at refrigerated temperatures for up to 5 days.
|
Patient Preparation:
|
None
|
Sample Rejection:
|
Mislabeled or unlabeled specimen; specimens other than serum; gross hemolysis
|
Interpretive
|
Reference Range:
|
Age:
|
Range:
|
≤7 days:
|
3.2 - 21.0 uIU/mL
|
≥8 days:
|
0.5 – 4.8 uIU/mL
|
Critical Values:
|
N/A
|
Limitations:
|
Heterophile antibodies may interfere with immunoassay testing.
|
Methodology:
|
3rd Generation Competitive Chemiluminescent Immunoassay
|
References:
|
Siemens Immulite 2000 Third Generation TSH Product Insert (08/13/2008) Siemens Healthcare Diagnostics
|
DPC End User Procedure Manual Disk #0408111 (2005)
|
National Committee for Clinical Laboratory Standards (NCCLS) (2002) Clinical Laboratory Technical Procedure Manuals; Approved Guideline-Fourth Edition GP2-A4
|
Burtis CA, Ashwood ER, editors (1994) Tietz Textbook of Clinical Chemistry. 2nd ed. Philadelphia: W.B. Saunders
|
Biorad Immunoassay Plus Control Product Insert
|
Updates:
|
8/29/2005: Methold previously listed as Two Site Sandwich Immunoassay Direct Chemiluminescence standardized to WHO 3rd IRP reference material.
10/1/2008: Name change to include Sensitive.
|