Lab Dept:
|
Serology
|
Test Name:
|
COXSACKIE B ANTIBODY PANEL
|
General Information
|
Lab Order Codes:
|
COBA
|
Synonyms:
|
Myocarditis Antibodies
|
CPT Codes:
|
86658 x6 – Antibody; enterovirus
|
Test Includes:
|
Coxsackie B virus type 1 - 6 total antibodies
|
Logistics
|
Test Indications:
|
Useful for detecting total antibodies to coxsackie B virus types 1 – 6.
|
Lab Testing Sections:
|
Serology - Sendouts
|
Referred to:
|
Mayo Medical Laboratories forward to Focus Technologies (Test# 80247)
|
Phone Numbers:
Minneapolis:
Saint Paul:
|
|
612-813-6280
|
651-220-6550
|
Test Availability:
|
Daily, 24 hours
|
Turnaround Time:
|
2 - 5 days, test performed Sunday – Thursday.
|
Special Instructions:
|
Designate whether specimen is acute or convalescent.
|
Specimen
|
Specimen Type:
|
Blood
|
Container:
|
Red top tube
|
Draw Volume:
|
1.5 mL blood
|
Processed Volume:
|
0.5 mL serum
|
Collection:
|
Routine venipuncture
|
Special Processing:
|
Lab Staff: Centrifuge specimen, separate serum aliquot into a screw-capped round bottom plastic vial. Store and ship at refrigerated temperatures. Forward promptly.
|
Patient Preparation:
|
None
|
Sample Rejection:
|
Improperly labeled specimen
|
Interpretive
|
Reference Range:
|
<1:8 Antibody not detected
≥1:8 Antibody detected
Single titers ≥1:32 are indicative of recent infection. Titers of 1:8 or 1:16 may be indicative of either past or recent infection, since Complement Fixation antibody levels persist for only a few months. A four-fold or greater increase in titer between acute and convalescent specimens confirms the diagnosis.
Test Performed by:
Focus Diagnostic
5785 Corporate Avenue
Cypress, CA 90630-4750
|
Critical Values:
|
N/A
|
Limitations:
|
There is considerable crossreactivity among enteroviruses; however, the highest titer is usually associated with the infecting serotype.
|
Methodology:
|
Complement Fixation (CF)
|
References:
|
Mayo Medical Laboratories November 2010
|
Focus Technologies Web Page (Focus Test 40335) November 2010
|
Updates:
|
3/2/2004: Test moved from Lab Corp (Viromed) to MML (forward to Focus Technologies). Test previously measured IgG antibody, now measures total antibody.
|